PRINTABLE CABVIX CHECKLIST
Network rack
audit checklist.
Prepare the visit, capture the cabinet consistently, verify the physical paths and leave a record another technician can use.
Before attending the site
- Confirm the audit scope, sites, rooms and cabinets.
- Identify the customer or internal owner responsible for access and questions.
- Collect available rack elevations, port schedules, floor plans and previous reports.
- Confirm access requirements, inductions and safe working conditions.
- Prepare a consistent naming convention for sites, rooms, racks and hardware.
- Confirm which connection types must be traced and which may remain out of scope.
Location and cabinet identity
- Verify the site, building, floor, room and cabinet identifier.
- Record cabinet height, approximate location and front/rear orientation.
- Capture clear overall photographs where authorised.
- Record power, UPS or PDU equipment relevant to the documented scope.
- Note access constraints, damage, congestion or environmental concerns.
Installed hardware
- Record each device in its actual rack-unit position.
- Capture manufacturer, model, role and identifying label.
- Record serial or asset identifiers where required and authorised.
- Include shelves, fibre trays, cable managers and other passive hardware.
- Mark empty, obscured or inaccessible positions rather than assuming their state.
- Identify equipment that appears decommissioned but remains installed.
Ports and physical connections
- Identify patch panels and their port numbering direction.
- Record switch ports and the patch-panel ports connected to them.
- Capture lead colours, PoE requirements and operational tags where relevant.
- Trace uplinks, fibre paths, inter-rack links and carrier handoffs.
- Record directly connected shelf devices and other non-patch-panel connections.
- Mark occupied, unknown and unverified ports explicitly.
Outlets and endpoints
- Verify outlet labels against patch-panel positions.
- Record each socket separately on multi-port wall plates.
- Capture the outlet location on a plan or consistent room reference.
- Identify the connected endpoint or service where known.
- Record missing, duplicated or inconsistent labels for remediation.
Close-out and quality check
- Reconcile field records against supplied schedules and plans.
- Review unknown connections and unresolved conflicts with the site contact.
- Confirm photographs and evidence are attached to the correct location or item.
- Record defects, risks and recommended remediation separately from verified facts.
- Check that another technician can trace priority services from the completed record.
- Record the auditor, completion date and verification status.
- Issue or share the agreed handover report with authorised recipients.
Important
This checklist supports documentation work. It does not replace site safety procedures, electrical requirements, customer security controls or applicable cabling standards.